The VT560 Smoke Detector is designed to monitor the presence of smoke and fire indoors.
- Type of sensor: Analog sensor
- Measures: Smoke, fire
- Cable length: RJ11 / RJ12 6P4C, telephone cable 2m included
- Power consumption: 1 mW – No smoke 100 mW – Smoke detected
- Plug-and-play — automatically detected on any Vutlan analog port
- Place up to 100 m from the monitoring unit using RJS extension cables
Available in Israel exclusively through Somet Integration — local stock, pricing, project design, installation support and warranty.
VT560 Smoke Detector
The VT560 Smoke Detector is designed to monitor the presence of smoke and fire indoors.
This plug-and-play sensor easily connects to any analog port of Vutlan monitoring devices. It can be chained, allowing multiple smoke detectors to be connected to a single bus. The system interface then shows a single smoke detector connected to analog port!
The maximum amount of sensors can be extended using the VT408 / Sensor extension unit.
Key features
- Type of sensor: Analog sensor
- Measures: Smoke, fire
- Cable length: RJ11 / RJ12 6P4C, telephone cable 2m included
- Power consumption: 1 mW – No smoke 100 mW – Smoke detected
- Inputs / Outputs: Two ports 6P4C
- Plug-and-play — automatically detected on any Vutlan analog port
- Place up to 100 m from the monitoring unit using RJS extension cables
- Add more analog ports with the VT408 sensor extension unit
- Made in EU
| Type of sensor | Analog sensor |
| Sensing type | Photoelectric |
| Measures | Smoke, fire |
| Daisy chain | Yes, up to 10 sensors in a chain. The system will show all daisy chain sensors in one chain as one element. Any triggered sensor in a chain will trigger the element in the web interface. |
| Cable length | RJ11 / RJ12 6P4C, telephone cable 2m included |
| Power consumption | 1 mW – No smoke 100 mW – Smoke detected |
| Optimal | -10 °C to +55° C |
| Extended | -10 °C to +80° C |
| Storage temperature | -10 °C to +55° C |
| Operating humidity | 5 to 95 % (Non-Condensing) |
| Storage humidity | 5% to 95% (Non-Condensing) |
| Average lifespan | >=10 years |
| LED indication | Red LED |
| Inputs / Outputs | Two ports 6P4C |
| Mounting possibilities | On the сeiling |
| Max. distance from the unit | 150 m from the unit or extension module Maximum installation height 6 m Dimensions |
| Origin of goods | Made in EU |
| HS Code | 8531 10 950 |
| EAN | 8588009886235 |
- The Importance of Using VT560 to Improve Security
- Fire safety monitoring: the system detects the presence of smoke in the room.
- Installation in vulnerable areas: the sensor can be installed in rooms, buildings, server racks at a height of up to 3m.
Recommended Vutlan products to use with this item:
- VT560 Flyer
- VT560 online datasheet
- VT560 ackage content
- EMC test report
- CE EMC LVD ROHS certificate – LV units
- How to connect analog sensors
- How to configure analog sensors
- API: analog sensors
Documents are hosted by the manufacturer, Vutlan.
Request a quote
Somet Integration is the exclusive distributor of Vutlan in Israel. Get local pricing, stock availability, project design and technical support for the VT560.
Prefer to talk? Call 1-700-700-193, email somet@sometltd.com or message us on WhatsApp.