VT825G Data Center Monitoring Unit




Vutlan · Monitoring Units · Data Center
Gigabit data-center monitoring unit — environmental, power and access monitoring for server rooms and mid-size data centers, with redundant power and 4G backup.
- 8 plug-and-play analog ports + CAN bus for extension units and CAN sensors
- 16 dry-contact inputs, 2 latching relays 240V/10A + 2 × 12V relays
- Gigabit Ethernet · Web UI, SNMP v1/v2c/v3, REST API, Modbus TCP
- Redundant power — 230V AC and/or 24–48V DC inputs, optional battery
- 4G LTE modem slot — SMS/voice alerts and automatic network failover
- 1U 19″ rack unit · Made in EU
Available in Israel exclusively through Somet Integration — local stock, pricing, project design, installation support and warranty.
Total control over your data-center environment
The Vutlan VT825G is a 19″ rack-mount monitoring unit for server rooms and medium-size data centers. It collects data from plug-and-play sensors, dry contacts, Modbus and SNMP devices, runs automatic logic, and alerts your team by email, SMS, Telegram, SNMP traps or phone call — all from a built-in web interface, with no external server or license required.
Key features
- Sensors: 8 auto-detecting analog ports; extend with CAN bus devices and VT408 extension units
- Inputs & outputs: 16 dry-contact inputs, 2 latching relays (240V, 10A) and 2 × 12V relays
- Integration: SNMP v1/v2c/v3 (GET & traps), REST API, Modbus TCP read/write, Modbus RTU via VT485m, Syslog, FTP, SMTP
- Virtual sensors: ping, SNMP GET, timers, triggers and math elements that combine sensor data
- Logic schemes: automatic actions (relay switching, notifications) based on thresholds and events
- Alerts: email (up to 20 recipients), SMS & voice with 4G modem, web-to-SMS, SNMP traps, Syslog
- Security: HTTPS/TLS 1.3, VPN, RADIUS authentication, RFID user keys (with reader)
- Cameras: view up to 4 IP MJPEG cameras in the interface
- Network redundancy: with the 4G modem, the unit automatically switches to LTE if the LAN fails
- Power: single or redundant 230V AC / 24–48V DC inputs; 1–10 W consumption; EU energy class A
| Device Management | Web UI, SNMP, Rest API |
| LAN | 10/100/1000 Mbps |
| OS | Linux v.6.2 |
| Memory RAM | 128 Mb |
| CPU speed | 720 MHz |
| Clock | Built-in clock |
| Timer | Built-in watchdog |
| The maximum amount of sensors | 130 (physical sensors, dry contacts, relays) |
| The maximum amount of elements | 1000 (notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap, Dial task, and other elements) Networking / Protocol support |
| LTE Gateway mode | Internet access (routing for internal network) (modem ordered separately) |
| LTE Access mode | Internet access over LTE (modem ordered separately) |
| Network protocols | DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS (v1.0, v1.1, v1.2, v1.3) |
| Modbus RTU | Using extension VT485m (ordered separately) |
| RS485 / OSDPv2 | reader access control: Using extension VT485R (ordered separately) |
| Modbus TCP / IP | Read/Write |
| Static routing | Yes |
| Dynamic DynDNS | Yes |
| Access via RADIUS server | Yes |
| VPN | Secure data communications; secure change of connection between LTE and LAN |
| SSL installation | Yes Alerts / Notifications |
| Alert types | E-mail, FTP log, Syslog, SMTP, SNMP Traps, SMS (Modem is ordered separately), Web-to-SMS A maximum number of “mail to” recipients in an E-mail notification: 20 A maximum number of “SMS to” recipients in an SMS notification: |
| Relay outputs | x2 Latching relays 240V*10A |
| Relays outputs | x2 12V 0.25A Virtual sensors |
| Pings | Built-in function for server pinging. Test the reachability of a host in a network. |
| IP cameras | Connect up to x4 IP MJPEG cameras with a proxy via the master module. Only view, no record. |
| Get SNMP | Read data from external equipment via SNMP PDU GET (v1/2c) |
| User keys | Add users who have access using an RFID reader. |
| Logic schemes | Used to specify automatic actions to events that occur in the system. |
| Timers | Allows you to plan the events in the system. |
| Triggers | Generate events in the system if logic is triggered. |
| SNMP traps | Yes |
| Virtual Math element | Combine several sensor data and calculate new data |
| Logic schemes | Automate events in the system based on alert thresholds and other events. Power |
| Energy efficiency | Grad A (EU Energy level) |
| Power input (230V AC) | Two inputs option |
| Power input (24 ÷ 48V DC) | Two inputs option |
| Power input (12V DC) | Input |
| Fuse | 1A at the inlet |
| Min. power consumption | 1 W |
| Max. power consumption | 10 W |
| The maximum current load on the relay | 10А |
| Redundant power supply | AC/DC; DC/DC or a mix (built-in voltage monitor, voltage range 9-12.6V.) |
| Reduntant battery | Optional, ordered separately. Inputs |
| Analog port | x8 (6P6C for connection of an analog sensor. Extendable using CAN bus) |
| CAN port | x1 port, up to x24 devices in total (Use CAN-12V-1A for connecting more than 12 devices.) (24 max. recommended) |
| VT825G | 230V AC power input |
| VT825GG | Two 230V AC inputs — redundant power |
| VT825DC | 24–48V DC power input |
| VT825DCDC | Two 24–48V DC inputs — redundant power |
| VT825GDC | 230V AC + 24–48V DC inputs — redundant power |
| Option: VT7670E / VT7670G | 4G LTE modem — SMS, voice alerts, LTE failover |
| Option: VT485m / VT485r | Modbus RTU extension or OSDP v2 card-reader extension |
Not sure which configuration fits your site? Ask us — we will design it with you.
- Mid-size data centers — temperature, humidity, airflow, leak and power monitoring per row or room
- Server rooms & computer rooms — complete environmental and access supervision
- Critical infrastructure — early warning and automatic action before failures occur
- Telecom & network hubs — redundant power and LTE failover for remote management
- Colocation & enterprise IT — integrates with NMS, DCIM and BMS via SNMP, Modbus and REST API
Recommended Vutlan products to use with this item:
- VT500 — precision temperature sensor
- VT490 — temperature & humidity (CAN)
- VT460 — smoke, humidity & temperature
- VT520 — AC voltage monitor
- VT520DIN — DIN-rail AC voltage monitor
- VT593 — spot leak sensor
- WLC — leak detection cable
- VT530 — door access sensor
- VT408 — sensor extension unit
- VT7670E — 4G LTE modem
- VT485m — Modbus RTU extension
- RJS cables — sensor extension cables
- VT103 — alarm beacon
Request a quote
Somet Integration is the exclusive distributor of Vutlan in Israel. Get local pricing, stock availability, project design and technical support for the VT825G.
Prefer to talk? Call 1-700-700-193, email somet@sometltd.com or message us on WhatsApp.









