VT855G Corporate Data Center Monitoring Unit




Vutlan · Monitoring Units · Corporate Data Center
Vutlan’s flagship monitoring unit for corporate data centers — maximum I/O, a 1 GHz processor, redundant power and full integration with your management systems.
- 8 analog ports + 2 CAN bus inputs
- 32 dry-contact inputs, 8 outputs and 4 relays
- Up to 150 physical sensors and 1,000 system elements
- Gigabit Ethernet · SNMP v1/v2c/v3, REST API, Modbus TCP
- Redundant power — 230V AC and/or 24–48V DC
- 4G/5G modem, Modbus RTU and OSDP v2 reader extensions
Available in Israel exclusively through Somet Integration — local stock, pricing, project design, installation support and warranty.
Total control over your infrastructure
The Vutlan VT855G Corporate Data Center Monitoring Unit is designed for large server rooms and corporate data centers that need high sensor density, many dry contacts and redundant power. It monitors temperature, humidity, voltage, access, smoke, dust, vibration, leakage, movement and airflow, integrates third-party equipment over SNMP and Modbus, and automates responses with logic schemes.
Key features
- I/O controller: 8 analog inputs, 2 CAN inputs, 32 dry-contact inputs, 8 dry-contact outputs, 4 relays, SD, USB
- Scale: up to 150 physical sensors and 1,000 elements (notifications, triggers, timers, logic, SNMP GET/traps and more)
- Processor: 1 GHz dual-core ARM Cortex-A7, Linux
- Integration: Web UI, SNMP v1/v2c/v3, REST API, Modbus TCP read/write; Modbus RTU via VT485m
- Access control: OSDP v2 card readers and keypads via VT485r; RFID user keys
- Alerts: email, Telegram, SMS and phone call (with modem), SNMP traps, Syslog, FTP log
- Security: HTTPS/TLS 1.3, VPN, RADIUS
- Network redundancy: automatic failover from LAN to LTE with the 4G modem
- Power: 230V AC, 24–48V DC or a mix, with redundant input options; EU energy class A
- Fully compatible with NVIDIA data-center environments (per manufacturer)
| Device Management | Web UI, SNMP, Rest API |
| LAN | 10/100/1000 Mbps |
| OS | Linux v.6.2 |
| Memory RAM | 128 Mb |
| CPU speed | 1 GHz |
| Clock | Built-in clock |
| Timer | Built-in watchdog |
| The maximum amount of sensors | 150 (physical sensors, dry contacts, relays) |
| The maximum amount of elements | 1000 (notifications, triggers, timers, logic, sensors, dry contacts, SNMP Get, SNMP Trap, Dial task, and other elements) Networking / Protocol support |
| LTE Gateway mode | Internet access (routing for internal network) (modem ordered separately) |
| LTE Access mode | Internet access over LTE (modem ordered separately) |
| Network protocols | DHCP; HTTP; HTTPS; SNMP v1, v2c, v3; SMTP; FTP; Syslog; TLS (v1.0, v1.1, v1.2, v1.3) |
| Modbus RTU | Using extension VT485m (ordered separately) |
| RS485 / OSDPv2 | reader access control: Using extension VT485R (ordered separately) |
| Modbus TCP / IP | Read/Write |
| Static routing | Yes |
| Dynamic DynDNS | Yes |
| Access via RADIUS server | Yes |
| VPN | Secure data communications; secure change of connection between LTE and LAN |
| SSL installation | Yes Alerts / Notifications |
| Alert types | E-mail, FTP log, Syslog, SMTP, SNMP Traps, SMS (Modem is ordered separately), Web-to-SMS A maximum number of “mail to” recipients in an E-mail notification: 20 A maximum number of “SMS to” recipients in an SMS notification: |
| Relay outputs | x2 Latching relays 240V*10A |
| Relays outputs | x2 12V 0.25A |
| Max. dry contact outputs | x8 (contact closures/digital outputs) Virtual sensors |
| Pings | Built-in function for server pinging. Test the reachability of a host in a network. |
| IP cameras | Connect up to x4 IP MJPEG cameras with a proxy via the master module. Only view, no record. |
| Get SNMP | Read data from external equipment via SNMP PDU GET (v1/2c) |
| User keys | Add users who have access using an RFID reader. |
| Logic schemes | Used to specify automatic actions to events that occur in the system. |
| Timers | Allows you to plan the events in the system. |
| Triggers | Generate events in the system if logic is triggered. |
| SNMP traps | Yes |
| Virtual Math element | Combine several sensor data and calculate new data |
| Logic schemes | Automate events in the system based on alert thresholds and other events. Power |
| Energy efficiency | Grad A (EU Energy level) |
| Power input (230V AC) | Two inputs option |
| Power input (24 ÷ 48V DC) | Two inputs option |
| Power input (12V DC) | Input |
| Fuse | 1A at the inlet |
| Min. power consumption | 1 W |
| Max. power consumption | 10 W |
| The maximum current load on the relay | 10А |
| Redundant power supply | AC/DC; DC/DC or a mix (built-in voltage monitor, voltage range 9-12.6V.) |
| Reduntant battery | Optional, ordered separately. Inputs |
| Analog port | x8 (6P6C for connection of an analog sensor. Extendable using CAN bus) |
| VT855G | 230V AC power input |
| VT855GG | Two 230V AC inputs — redundant power |
| VT855DC | 24–48V DC power input |
| VT855DCDC | Two 24–48V DC inputs — redundant power |
| VT855GDC | 230V AC + 24–48V DC inputs — redundant power |
| Option: VT7670E / VT7670G | 4G LTE modem — SMS, voice alerts, LTE failover |
| Option: VT485m or VT485r | Modbus RTU extension or OSDP v2 reader/keypad extension (one of the two) |
Planning a data-center project? Contact us for a full design with sensors, cabling and integration.
- Corporate & enterprise data centers — high-density environmental and power monitoring
- Multi-room facilities — many doors, racks and cooling units on one controller via 32 dry contacts
- Access-controlled server rooms — OSDP v2 readers and RFID keys
- DCIM / BMS integration — SNMP, Modbus and REST API towards your management platforms
- Critical sites requiring redundancy — dual power inputs and LTE network failover
Recommended Vutlan products to use with this item:
- VT500 — precision temperature sensor
- VT490 — temperature & humidity (CAN)
- VT460 — smoke, humidity & temperature
- VT520 — AC voltage monitor
- VT520DIN — DIN-rail AC voltage monitor
- VT593 — spot leak sensor
- WLC — leak detection cable
- VT530 — door access sensor
- VT408 — sensor extension unit
- VT7670E — 4G LTE modem
- VT485m — Modbus RTU extension
- RJS cables — sensor extension cables
- VT103 — alarm beacon
- VT408D — sensor extension unit
Request a quote
Somet Integration is the exclusive distributor of Vutlan in Israel. Get local pricing, stock availability, project design and technical support for the VT855G.
Prefer to talk? Call 1-700-700-193, email somet@sometltd.com or message us on WhatsApp.