Delta CW-29 – In-Row Cooling


Delta · Data Center · Cooling
Delta’s RowCool CW delivers exceptional performance for high-temperature chilled water applications with its advanced heat exchanger design.
- Total Cooling Capacity(1): 30.8 kW
- Sensible Cooling Capacity(1): 30.2 kW
- Total Cooling Capacity(2): 37.1 kW
- Sensible Cooling Capacity(2): 37.1 kW
- Dual Power Feed: supports dual power inputs, suitable for any tier level of power reliability
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta CW-29 – In-Row Cooling
RowCool for effective heat removal in data centers
Delta’s RowCool CW delivers exceptional performance for high-temperature chilled water applications with its advanced heat exchanger design. Featuring industryleading cooling capabilities, the RowCool CW enhances overall efficiency in data center precision cooling systems. Each unit offers a remarkable cooling capacity of up to 95kW, making it ideal for data centers requiring hundreds of kW. Designed for high efficiency and high density, the RowCool CW ensures reliable, efficient cooling for even the most demanding environments.
High power density rack area
Environment that requires precise environmental control
The CW-29 is part of the Delta In-Row Cooling, Chilled Water, RowCool 29/43/70/95 kW range (Cooling). See all Delta Data Center Infrastructure.
| Model | CW-29 |
| Total Cooling Capacity(1) | |
| Total Cooling Capacity(1) | 30.8 kW |
| Sensible Cooling Capacity(1) | |
| Sensible Cooling Capacity(1) | 30.2 kW |
| Total Cooling Capacity(2) | |
| Total Cooling Capacity(2) | 37.1 kW |
| Sensible Cooling Capacity(2) | |
| Sensible Cooling Capacity(2) | 37.1 kW |
| Total Cooling Capacity | |
| Total Cooling Capacity | 28.8 kW(3) |
| Sensible Cooling Capacity | |
| Sensible Cooling Capacity | 28.8 kW(3) |
| Deployment | |
| Coolant Type | Chilled Water |
| Piping Connection Location | Top/Bottom |
| Chilled Water Flow Rate | |
| Chilled Water Flow Rate | 68.3 LPM |
| Airflow Rate | |
| Airflow Rate | 2902 CFM |
| Air Discharge Direction | Front |
| Heater | |
| CW-70/95 | Finned Tube (Optional) |
| Humidifier | |
| CW-70/95 | Electrode (Optional) |
| Nominal Power Supply Voltage | |
| Nominal Power Supply Voltage | 220/230 Vac, 1P2W+PE |
| Operating Voltage Range | |
| Operating Voltage Range | 198-242 Vac |
| Frequency | 50/60 Hz |
| Maximum Power Consumption | |
| Maximum Power Consumption | 1 kW |
| Dual Power Feed | Standard |
| Dimensions (W x D x H) | |
| CW-29/43 | 300 x 1090 x 2000 mm |
| CW-70/95 | 600 x 1090 x 2000 mm |
| Net Weight | |
| Net Weight | 185 kg |
| Communication Interface | |
| Display | LCD+LED indicators |
| Protocols | SNMP, Modbus RTU |
| Environment | |
| Operating Temperature | 4 to 40°C |
| Humidity | 30-85% |
| Conformance | |
| Safety | CE |
| Seismic Rating | GR63 Zone 4 |
| Features | |
| Leak Detection | Standard |
| Remote Rack Temperature | Standard |
| Drain Pump | Optional |
| Reheat and Humidifier Lockout | Optional |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
High Availability
- Dual Power Feed: supports dual power inputs, suitable for any tier level of power reliability
- Redundant Fan System: fans automatically adjust speeds if one fails, ensuring continuous airflow
- Hot-Swappable Parts: replace power modules and fans without downtime (applicable for CW-29 and CW-43 models)
- 1+1 Redundant Power Modules: enhance reliability (available on select models)
- Real-Time Monitoring: tracks water flow and leaks for immediate troubleshooting
High Efficiency
- Optimized Design: enhances cooling efficiency for high-temperature chilled water systems
- Smart Fan Control: EC fans adjust speeds in real-time based on load changes, minimizing power waste
- Effective Heat Removal: closely integrates with IT heat loads for effective heat dissipation
High Flexibility
- Flexible Installation: supports top or bottom piping and wiring
- Filter Choices: high-efficiency (MERV 8) or washable (MERV 1) filters available
- Easy Mobility: casters make installation and repositioning easy
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● 43 kW ● ● ● ● For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.
Downloads
- Delta CW-29 – In-Row Cooling – datasheet (PDF)
- In-Row Cooling, Chilled Water, RowCool 43 kW (Leaflet) : UL for Northa America
- In-Row Cooling, Chilled Wate, RowCool 29/43 kW (User Manual)
- In-Row Cooling, Chilled Water, RowCool 70 kW (User Manual)
- In-Row Cooling, Chilled Water, RowCool 95/120/260 kW (User Manual)
Buy & Support
Somet Integration is the official distributor of Delta Electronics critical-infrastructure products in Israel. We provide project sizing, quotations, delivery, installation, commissioning, maintenance contracts and battery replacement.
Request a quote
Get local pricing, availability, sizing and installation for the Delta CW-29 – In-Row Cooling from Somet Integration.