Delta NT-60K UPS – 60 kVA / 48 kW
Delta · UPS · Ultron
Designed for operations in the harshest of environmental conditions, the Ultron NT Series UPS is an industrial UPS system offering proven reliability and flexibility to secure electrical power supplies in critical applications.
- Power Rating: 60 kVA / 48 kW
- Weight: 506 kg
- Available from 20 to 4,000 kVA (8 x 500 kVA in parallel).
- Parallel redundancy without requiring extra hardware to increase reliability.
- Optional harmonic filter and 12-pulse rectifier.
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta NT-60K UPS – 60 kVA / 48 kW
Enterprise power customized for greatest reliability
Designed for operations in the harshest of environmental conditions, the Ultron NT Series UPS is an industrial UPS system offering proven reliability and flexibility to secure electrical power supplies in critical applications.
The three phase UPS featuring customized I/P-O/P ratings brings best-in-class technology, a long product lifetime (minimal servicing), N+X parallel operations for increased redundancy deployment, and a broad range of available power ratings.
The Ultron NT Series UPS lets you effectively respond to increasing demands placed on infrastructure in commercial and industrial facilities by offering N+1 functionality. Efficiency is a key feature with 93% system efficiency at full load and continuing to 25% load.
In an era where big data is dominant, increased power protection requires a solution with unmatched power performance. The Ultron NT Series UPS system fulfills your uninterruptible power requirements.
The NT-60K is part of the Delta NT Series, Three Phase, 20-500 kVA range (Ultron). See all Delta UPS Systems.
| Model | NT-60K |
| NT-120K, NT-160K, NT-200K, NT-260K, NT-320K, NT-400K, NT-500K | |
| Power Rating | |
| Power Rating | 60 kVA / 48 kW |
| NT-120K | 120 kVA / 96 kW |
| NT-160K | 160 kVA / 128 kW |
| NT-200K | 200 kVA / 160 kW |
| NT-260K | 260 kVA / 208 kW |
| NT-320K | 320 kVA / 256 kW |
| NT-400K | 400 kVA / 320 kW |
| NT-500K | 500 kVA / 400 kW |
| Input | |
| Nominal Voltage | 380/400/415 Vac, 3P4W+PE |
| Voltage Range | 305-499 Vac (100% load) |
| Frequency Range | 45-65 Hz |
| Total Harmonic Distortion (THDi) | < 3%(1) |
| Connection | Single or dual feed |
| Output | |
| Nominal Voltage | 380/400/415 Vac, 3P4W+PE |
| Voltage Regulation | ±1% |
| Frequency | 50/60 ± 0.01 Hz |
| Total Harmonic Distortion (THDv) | < 3% (linear load) |
| Power Factor | 0.8(2) |
| Overload Capability | ≤ 110%: 60 min, 111-125%: 10 min, 126-150%: 1 min |
| Current Crest Ratio | 3:1 |
| Interface | |
| Standard | RS232 x 1, RS485 x 2, SMART slot x 1, Output dry contact x 6 |
| Other Features | |
| Parallel Redundancy | Up to 8 units |
| Emergency Power Off | Local and remote |
| SRAM Event Log | 500 records |
| Input Harmonic Improvement | Optional harmonic filter and 12-pulse rectifier |
| AC-AC | |
| NT-30K/40K | 91% |
| NT-50K/60K | 91.5% |
| NT-80K/100K | 92% |
| NT-120~200K | 92.5% |
| NT-260~500K | 93% |
| ECO Mode | |
| NT-30~500K | > 97.5% |
| Environment | |
| Operating Temperature | 0 to 40ºC |
| Relative Humidity | 0-95% (non-condensing) |
| IP Protection | IP20 |
| Audible Noise (at 1.5 meters) | |
| NT-20~40K | ≤ 60 dB |
| NT-50~120K | ≤ 65 dB |
| NT-160K/200K | ≤ 68 dB |
| NT-260~400K | ≤ 72 dB |
| NT-500K | ≤ 77 dB |
| Dimensions(W x D x H) | |
| NT-20~80K | 600 x 800 x 1400 mm |
| NT-100K/120K | 800 x 830 x 1700 mm |
| NT-160K/200K | 1200 x 830 x 1700 mm |
| NT-260~400K | 1600 x 995 x 1950 mm |
| NT-500K | 1900(3) x 995 x 1950 mm |
| Weight | |
| Weight | 506 kg |
| NT-120K | 745 kg |
| NT-160K | 1050 kg |
| NT-200K | 1085 kg |
| NT-260K | 1680 kg |
| NT-320K | 1720 kg |
| NT-400K | 1920 kg |
| NT-500K | 3110 kg(3) |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
Availability
- Available from 20 to 4,000 kVA (8 x 500 kVA in parallel).
- Parallel redundancy without requiring extra hardware to increase reliability.
- Optional harmonic filter and 12-pulse rectifier.
- Redundant auxiliary power and control circuit ensures higher reliability.
- Inbuilt maintenance and static bypass switch.
Flexibility
- Multi-language LCD display and LED status indicators.
- RS-232, RS-485 and six programmable dry contact outputs.
- Compatible with generator installation and unbalanced loads.
- Optional external battery cabinet for longer backup time.
Low Total Cost Of Ownership
- Parallel expansion as your business grows and consequently saves initial investment.
- Wide input voltage range extends battery lifetime.
- Economy mode saves energy and operating cost.
- Common battery installation saves initial investment.
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● 15-100 kVA (480 V) ● ● ● ● ● ● ● For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.
Downloads
- Delta NT-60K UPS – 60 kVA / 48 kW – datasheet (PDF)
- NT Series 15-100 kVA UPS, 480V (Leaflet) : for North America
- NT Series 20-500 kVA UPS (Leaflet) : for SEA
- NT Series 10-500 kVA UPS (User Manual)
Buy & Support
Somet Integration is the official distributor of Delta Electronics critical-infrastructure products in Israel. We provide project sizing, quotations, delivery, installation, commissioning, maintenance contracts and battery replacement.
Request a quote
Get local pricing, availability, sizing and installation for the Delta NT-60K UPS – 60 kVA / 48 kW from Somet Integration.
Prefer to talk? Call 1-700-700-193, email somet@sometltd.com or message us on WhatsApp.