Delta DPS-300K UPS – 300 kVA / 300 kW


Delta · UPS · Ultron
The Next Generation UPS Answering the Demand of Large Data Centers and Colocations
- Power Rating: 300 kVA / 300 kW
- Charge Current: 90 A
- Dimensions (W x D x H): 600* x 900 x 2000 mm
- Weight: 515 kg
- Supports up to 10 MW power capacity with the parallel redundancy and expansion up to 8 units
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta DPS-300K UPS – 300 kVA / 300 kW
The Next Generation UPS Answering the Demand of Large Data Centers and Colocations
Delta’s superior Ultron DPS series 300-1200 kVA UPS supports unity output power factor to deliver up to 10 MW power capacity to meet the demands for large data centers and colocations that require higher power capacity. The Ultron DPS series guarantees the highest level of system reliability and resiliency by supporting self-detection of key components with pre-warning function, multilayered redundancy design, and complete power rating coverage. Moreover, the DPS series supports advanced manageability. Key environment parameters, and event analysis can all be monitored via local 10” LCD monitor and remotely. Along with optional battery management software, the DPS series enables users to achieve predictive maintenance and minimize system downtime, while lowering the total cost of ownership (TCO).
The DPS-300K is part of the Delta DPS Series UPS, Three Phase, 300/400/500/600/800/1000/1200 kVA range (Ultron). See all Delta UPS Systems.
| Model | DPS-300K |
| DPS-800K / DPS-1000K / DPS-1200K | |
| Power Rating | |
| Power Rating | 300 kVA / 300 kW |
| Input | |
| Nominal Voltage | 220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G) |
| Voltage Range | 176/304~276/478 Vac (full load) |
| Current Harmonic Distortion | < 3% (with Full Linear Load) |
| < 5% (with Full Non-linear Load) | |
| Power Factor | > 0.99 |
| Frequency Range | 40~70 Hz |
| Output | |
| Voltage | 220/380 Vac, 230/400 Vac, 240/415 Vac (3-phase, 4-wire + G) |
| Voltage Harmonic Distortion | < 1.5% (Linear Load) |
| < 5% (Non-linear Load) | |
| Voltage Regulation | ± 1% (static), ± 5% (dynamic) |
| Output Power Factor | 1 |
| Frequency | 50/60 Hz (Auto-Selectable) |
| Overload Capability | ≤ 125%: 10 min |
| ≤ 150%: 1 min | |
| >150%: 1 sec | |
| Display | 10” Color Touch Panel |
| Interface | |
| Standard | RS232, Parallel port, USB, Modbus RS485, Input dry contact, Output dry contact, SNMP card inbuilt in touch screen |
| Optional | Relay I/O card, Battery cabinet temperature sensor cable |
| Conformance | Safety: CE |
| Efficiency | |
| AC-AC | Up to 96.5% |
| ECO Mode | 99% |
| Battery | |
| Type | VRLA, LiB |
| Charge Current | |
| Charge Current | 90 A |
| Battery Quantity | 30~46 pcs |
| Environment | |
| Operating Temperature | 0~40℃ |
| Relative Humidity | 0~95% (non-condensing) |
| IP Protection | IP20 |
| Others | |
| Parallel Redundancy and Expansion | Maximum 8 units |
| Emergency Power Off | Remote and local |
| Dimensions (W x D x H) | |
| Dimensions (W x D x H) | 600* x 900 x 2000 mm |
| DPS-400K/500K/600K | 1200* x 900 x 2000 mm |
| DPS-1000K/1200K | 2450 x 900 x 2000 mm |
| Weight | |
| Weight | 515 kg |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
Ultimate Availability
- Supports up to 10 MW power capacity with the parallel redundancy and expansion up to 8 units
- Redundancy components and dual CAN bus ensures system availability
- Proactive detection of key component status for early diagnosis on UPS malfunction
- Intelligent battery health diagnosis enables better battery maintenance and replacement
- Advanced event analysis, including 10,000 event logs, waveform capturing and key paremeters recording, to detect UPS abnomality and ensure higher availability
Excellent Performance
- The industry’s leading power density and smallest footprint with the design of both top/bottom cable entry* and inbuilt switches (* For DPS-300K, only top cable entry is available)
- Unity output power factor guarantees no-rating and provides 100% kW
- AC-AC efficiency of up to 96.5% and 99% in ECO mode resulting in marked energy cost savings
- Supports both VRLA and environment-friendly Li-ion batteries
Sophisticated Manageability and Flexibility
- User-friendly 10” color touch panel simplifies local UPS management
- Environment information, such as security, water, fire, and temperature can be integrated and monitored via the LCD panel of the UPS
- If the UPS is equipped with an external battery management system, the battery information can be integrated and monitored via the LCD panel of the UPS
- Fully front access and modular design of key components shortens the mean time to repair (MTTR)
- Flexible battery quantity of 30-46 pcs achieves optimal battery investment
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● ● ● ● ● ● ● ● For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.
Downloads
- Delta DPS-300K UPS – 300 kVA / 300 kW – datasheet (PDF)
- DPS Series 300-1200 kVA UPS (Leaflet)
- DPS Series 300/400/500/600 kVA UPS (User Manual)
- DPS Series 800/1000/1200 kVA UPS (User Manual)
Buy & Support
Somet Integration is the official distributor of Delta Electronics critical-infrastructure products in Israel. We provide project sizing, quotations, delivery, installation, commissioning, maintenance contracts and battery replacement.
Request a quote
Get local pricing, availability, sizing and installation for the Delta DPS-300K UPS – 300 kVA / 300 kW from Somet Integration.
Prefer to talk? Call 1-700-700-193, email somet@sometltd.com or message us on WhatsApp.