Delta Liquid-to-Liquid Coolant Distribution Unit, GoCool-1500
Delta · Data Center · Cooling
The increasing demand for high-performance computing and advanced GPUs highlights the limitations of aircooling.
- Maximize energy saving: cuts power consumption, surpassing traditional air cooling
- Space optimization: compact design enables closer server placement further reducing Capex
- Uninterrupted operation: dual power feed with ATS ensures continuous CDU operation
- Optimized redundancy design: ensures no single point of failure in the system
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta Liquid-to-Liquid Coolant Distribution Unit, GoCool-1500
The increasing demand for high-performance computing and advanced GPUs highlights the limitations of aircooling. Delta’s GoCool L2L CDU offers a superior alternative, providing effective separation of facility and secondary circuits as well as precise control over flow, pressure, temperature, and coolant quality. It excels in managing high-density thermal load, maximizing computing power while minimizing data center PUE. The GoCool L2L CDU ensures operational reliability by preventing condensation and guarantees quality with its stainless steel plumbing and coolant filtration. Elevate your data center performance—engineered for the future of high-performance computing.
Part of the Delta Data Center Infrastructure portfolio · Cooling.
| Model | GoCool-1500 |
| Nominal Cooling Capacity | 1500 kW @6°C approach, 1500 LPM secondary flow rate, 1300 LPM primary flow rate, 1.0 LPM/kW |
| 1375 kW @6°C approach, 1650 LPM secondary flow rate, 1300 LPM primary flow rate, 1.2 LPM/kW | |
| 1250 kW @5°C approach, 1500 LPM secondary flow rate, 1300 LPM primary flow rate, 1.2 LPM/kW | |
| 1016 kW @4°C approach, 1524 LPM secondary flow rate, 1300 LPM primary flow rate, 1.5 LPM/kW | |
| Primary Side | |
| Coolant Type | Water |
| Nominal Coolant Flow Rate | 1300 LPM, 17°C primary inlet temperature |
| Operation Pressure Drop | 114 kPa |
| Coolant Filter | 500 μm with bypass loop to enable hot-swappable |
| Secondary Side | |
| Coolant Type | 25%PG |
| Nominal Coolant Flow Rate | 1524 LPM |
| Approach Temperature | 4°C |
| Coolant Filter | 50 μm with isolation valves to enable hot-swappable (upgradeable to 25 μm) |
| External Pressure Drop | 331 kPa |
| Power Supply | |
| Nominal Power Supply Voltage | 380/400/415/480 Vac, 3P3W+PE |
| Operating Voltage Range | 342-528 Vac |
| Frequency | 50/60 Hz |
| Dual Power Feed | Standard |
| Automatic Transfer Switch | Standard |
| MCU Controls | Standard |
| Power Feed Location | Top |
| Deployment | |
| Primary Connection | 4″ sanitary ferrule |
| Secondary Connection | 4″ sanitary ferrule |
| Piping Connection Location | Top |
| Physical | |
| Dimensions (W x D x H) | 1200 x 1200 x 2300 mm |
| Clearance | Front: 1200 mm, Rear: 800 mm |
| Net Weigh | With coolant: 1900 kg, Without coolant: 1600 kg |
| Noise Level | < 76 dBA (at 1 m) |
| Communication Interface | |
| Display | 10″ color touchscreen |
| Protocols | SNMP, Modbus RTU, Modbus TCP/IP, BACnet |
| Monitoring | Primary Side: Temp. (Inlet/Outlet), Flow rate, Pressure (Inlet/Outlet, Filter ΔP) |
| Secondary Side: Temp. (Supply/Return), Flow rate, Pressure (Supply/Return, Filter ΔP) | |
| Dew-point Temp. | |
| Conformance | |
| Safety | CE, UL/CSA 60335 |
| Features | |
| ⦁ Leak Detection | Standard |
| ⦁ Dew Point Monitor | Standard |
| ⦁ Control Sensor Redundancy | Standard |
| ⦁ Variable Frequency Drivers (VFD) | Standard |
| ⦁ Expansion Vessel | Standard |
| ⦁ Filling Tank | Upgradeable to have |
| ⦁ Auto-restart Function | Standard |
| ⦁ Coolant Healthy Measurement | pH sensor |
| ⦁ Pump Redundancy | 3+1(N+1) or 4 (N mode) |
| ⦁ Grouping Control | Standard |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
Cost Effective
- Maximize energy saving: cuts power consumption, surpassing traditional air cooling
- Space optimization: compact design enables closer server placement further reducing Capex
- Flexible integration: supports direct-to-chip and Rear Door Heat Exchanger (RDHx) application, adapting to existing setups and blending air and liquid cooling for future upgrades
High Reliability
- Uninterrupted operation: dual power feed with ATS ensures continuous CDU operation
- Optimized redundancy design: ensures no single point of failure in the system
- Leak detection: instant alarms with configurable response for efficient pumping action
- Durable construction: stainless steel plumbing with 50-micron filters for long-term coolant quality
Easy Management
- Intuitive interface: 10-inch color touchscreen displays real-time system status
- Efficient control: group and manual control enhance system management and reliability
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● ● ● ● ● ● ● ● ● For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.