Delta DPM-1500K UPS Gen2 (400 V) – 1500 kVA / 1500 kW
Delta · UPS · Ultron
Selected by leading global cloud providers, Delta’s DPM Gen2 introduces advanced features for enhanced efficiency and reliability.
- Power Rating: 1500 kVA / 1500 kW
- AC-AC efficiency up to 97.3%, efficiency optimization at light loads saves energy costs
- Clean mode (voltage independent mode) up to 99% efficient guarantees the optimum power condition while maintaining the highest level of efficiency
- Optimizes energy cost with off-peak charging, avoiding peak-time expense
- Elevates grid stability through responsive demand reduction and fast frequency regulation, triggers upon utility requests for eligible bill subsidies
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta DPM-1500K UPS Gen2 (400 V) – 1500 kVA / 1500 kW
Uplevel Performance, Ensure Protection
Selected by leading global cloud providers, Delta’s DPM Gen2 introduces advanced features for enhanced efficiency and reliability. This includes OPEX savings with up to 97.3% AC-AC efficiency and improved grid stability. Synchronized Multiple Bus (SMB) and parallel scalability ensures flawless reliability, making it the ideal solution for fortified hyperscale data centers.
The DPM-1500K is part of the Delta DPM Gen2 Series UPS, 250-1750 kVA, 380/400/415 Vac range (Ultron). See all Delta UPS Systems.
| Model | DPM-1500K |
| DPM-1250K, DPM-1500K(1), DPM-1750K(1) | |
| Power Rating | |
| Power Rating | 1500 kVA / 1500 kW |
| Parallel Configuration | Up to 8 units |
| Input | |
| Nominal Voltage | 380/ 400/ 415 Vac, 3P3W+PE or 3P4W+PE |
| Voltage Range | 323-477 Vac (100% load) |
| Frequency Range | 40-70 Hz |
| Total Harmonic Distortion (THDi) | < 3% (100% resistive load) |
| Power Factor | > 0.99 (100% load) |
| Short Circuit Withstand Rating | |
| DPM-250-750K | 65 kA |
| DPM-1000-1750K | 100 kA |
| Connection | Single or dual feed |
| Output | |
| Nominal Voltage | 380/ 400/ 415 Vac, 3P3W+PE or 3P4W+PE |
| Voltage Regulation | ±1% (static) |
| Frequency | 50/60 ± 0.05 Hz |
| Total Harmonic Distortion (THDv) | < 1% (linear load) |
| Power Factor | 1 |
| Overload Capability | < 110%: continues, 110-125%: 10 mins, 126-150%: 1 min, > 150%: 1 sec |
| Current Crest Ratio | 3:1 |
| Efficiency | |
| Online Mode | Up to 97.3% |
| Clean Mode (VI) | Up to 99% |
| Battery | |
| Battery Type | VRLA, Vented lead-acid, Lithium-ion, Ni-Zinc |
| Nominal Voltage | 480 Vdc |
| Quantity | 34-35(2), 36-46 pcs (VRLA 12 V) |
| Charge Current | |
| Protection Design | Battery shunt trip x1, Battery temperature detection x4, Battery breaker status dry contact x1 |
| Communication Interface | |
| Display | 10-inch color touchscreen |
| Port | Smart slot x2, Modbus (RS-485) port x1, REPO port x1, Input dry contact x6, Output dry contact x6, Synchronized Multiple Bus (SMB) x2, Breaker status detection x4, EMS/Console port x1, Ethernet x1 |
| Protocols | SNMP, Modbus RTU, Modbus TCP/IP, HTTP(S), SNTP, SMTP, BOOTP, DHCP |
| Environment | |
| Operating Temperature | 0 to 40°C |
| Humidity | 0-95% (non-condensing) |
| Altitude | 0-2,000 m (derating 1%/100m from 1,001-2,000 m) |
| Conformance | |
| Safety | CE, UL |
| EMC | IEC 62040-2, FCC Class A |
| Performance | IEC 62040-3 |
| Sustainability | RoHS, REACH, Energy Star 2.0(3) |
| Features | |
| Standard | ⦁ Advance power walk-in for generator |
| ⦁ Backfeed protection with contactor | |
| ⦁ Burn-in test without load bank | |
| ⦁ Cold start function | |
| ⦁ Synchronized multiple bus (SMB) | |
| ⦁ Frequency conversion | |
| ⦁ Battery shunt trip | |
| ⦁ Auxiliary power 48 Vdc for shunt trip | |
| ⦁ Failure prediction | |
| Optional | ⦁ Grid interactive |
| ⦁ Software integration with Delta Lithium-ion battery BMS | |
| ⦁ DC battery ground fault detector | |
| ⦁ Integrated battery switch cabinet | |
| ⦁ IR scan window | |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
OPEX Savings
- AC-AC efficiency up to 97.3%, efficiency optimization at light loads saves energy costs
- Clean mode (voltage independent mode) up to 99% efficient guarantees the optimum power condition while maintaining the highest level of efficiency
- Optimizes energy cost with off-peak charging, avoiding peak-time expense
- Elevates grid stability through responsive demand reduction and fast frequency regulation, triggers upon utility requests for eligible bill subsidies
Impeccable Reliability
- Assures smooth power transitions with integrated Synchronized Multiple Bus (SMB), minimizing transformer inrush currents and maintaining balanced power from dual sources
- Parallels up to 8 units for redundancy or expansion, supported by N+1 internal redundancy in power modular configuration
- Maximizes UPS performance and lifespan with self-diagnosis and key component analysis
Ultimate Availability
- Lithium-ion battery ready. Adjustable battery charging voltage adapts to multiple types of batteries
- Seamless power shifts to generator with an advance power walk-in function, pausing during frequency issues for smooth transitions without unnecessary generator sizing expansion
- Grid interactive application. Provides corrective operation for unstable renewal energy sources with an innovative topology design that handles grid and battery power at the same time
- Easy mounting/cabling that supports both top and bottom cable entry and full front access
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● ● ● ● ● ● ● ● ● For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.
Downloads
- Delta DPM-1500K UPS Gen2 (400 V) – 1500 kVA / 1500 kW – datasheet (PDF)
- DPM Gen2 Series UPS (Brochure)
- DPM Gen2 Series 132/250 kVA UPS, 400V (User Manual)
- DPM Gen2 Series 1000/1250 kVA UPS, 400V (User Manual) : CE
- DPM Gen2 Series 1000/1250 kVA UPS, 400V (User Manual) : CE & UL – for North America
Buy & Support
Somet Integration is the official distributor of Delta Electronics critical-infrastructure products in Israel. We provide project sizing, quotations, delivery, installation, commissioning, maintenance contracts and battery replacement.
Request a quote
Get local pricing, availability, sizing and installation for the Delta DPM-1500K UPS Gen2 (400 V) – 1500 kVA / 1500 kW from Somet Integration.
Prefer to talk? Call 1-700-700-193, email somet@sometltd.com or message us on WhatsApp.