Delta Active Power (Harmonic) Filter




Delta · Power Quality · Power Quality
Delta’s PQC Series APF is connected in parallel with non-linear loads, and uses one set of current transformers (CT) to detect the load current.
- Models: AC 208 V, AC 400 V, AC 690 V
- Multifunctional: Harmonic, reactive power and imbalance compensation
- Harmonic Elimination Range: 2nd~50th order (Selectable)
- High harmonic filtering rate: Up to 98%
- Excellent reactive compensation: High speed, Precise (-0.99 ≤ PF≤ 0.99), Step-less, Bi-directional (capacitive and inductance) compensation
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta Active Power (Harmonic) Filter
Delta’s PQC Series APF is connected in parallel with non-linear loads, and uses one set of current transformers (CT) to detect the load current. It calculates each order harmonic current by FFT algorithms in its DSP microchips, and then generates a compensating current with the same amplitude but opposite phase angles to the detected harmonic current, which cancels out the original load harmonics.
The PQC series APF not only eliminates harmonic current from the load side, but it also mitigates harmonic voltage caused by harmonic currents. The APF system can also improve power factor (PF) and correct load imbalances in the power system.
Note: CT is a critical part of the APF system, and it can be purchased by users themselves, following Delta’s suggestions on CT specification.
Delta PQC Series APF has a modular design, which adopted 3-level inverter topology with 3 pcs modular IGBT and DC capacitor components, and the Delta Active Power Filter system consists of one or several APF modules and a 7” or 10” HMI display.
Each APF module is an independent harmonic filtering system, and users can change the harmonic filtering system rating by adding or removing APF modules.
According to the mounting type, Delta PQC series APF can be divided into Modular APF (rack mounting) and wallmounted APF.
APF Module and Cabinet Solutions
According to cable terminal type, a modular APF can be divided into two types:.
Part of the Delta Power Quality portfolio · Power Quality.
| Rated Voltage | AC 208 V, AC 400 V, AC 690 V |
| Input Voltage Range | |
| AC 208 V | AC 166~250 V, AC 166~250 V |
| AC 400 V | AC 308~456 V, AC 308~480 V |
| AC 690 V | AC 384~880 V |
| Electric Connection | |
| AC 208 V | 3P4W, 3P3W |
| AC 400 V | 3P4W, 3P3W |
| AC 690 V | 3P3W |
| Rated Current per Module | |
| AC 208 V | 50 A, 75 A, 100 A, 150 A |
| AC 400 V | 30 A, 50 A, 75 A, 100 A. 150 A |
| AC 690 V | 100 A |
| Rated Current per Cabinet | |
| AC 208 V | 50~750 A (Module combination) |
| AC 400 V | 30~750 A (Module combination) |
| AC 690 V | 100~500 A (Module combination) |
| Rated Frequency | 50(60) Hz ± 10% |
| Input Voltage THD Range | ≤ 15% |
| Redundancy | Each module is an independent filtering system |
| Harmonic Elimination Range | 2nd~50th order (Selectable) |
| Harmonic Filtering Degree | 0~100% programmable per harmonic in Ampere value |
| Harmonic Filtering Performance | Filter up to 98% harmonics at rated load |
| THDv < 3%, THDi < 5% after filtering | |
| Reactive Power Compensation Capability | Both inductive and capacitive reactive power |
| Reactive Power Compensation Performance | Cosφ ≥ 0.99 after compensation (if the APF capacity is sufficient) |
| Imbalance Correction Capability | Mitigate negative and zero sequence |
| Full Response Time | < 10 ms |
| Instant Response Time | < 100 us |
| Thermal Loss | |
| AC 208 V | ≤ 5% of APF rated capacity |
| AC 400/690 V | ≤ 3% of APF rated capacity |
| Output Current Limitation | Automatic (100% rated capacity) |
| Parallel Expansion (System) | Up to 10 Racks (7 modules per cabinet) |
| MTBF | > 100,000 hours |
| Control Technology | |
| Switching Frequency | 30 kHz |
| Controller | DSP + FPGA |
| CT Position | Grid side or Load side |
| Waveform Display | Input Voltage waveform, Grid current waveform, Load current waveform and APF current waveform |
| Harmonic Current Histogram Display | Grid harmonic current and load harmonic current |
| Communication | Modbus RTU (RS-485), Modbus TCP/IP (Ethernet) |
| Physical Specification | |
| IP Grade of Cabinet | IP20, IP30, IP54, IP55 or customization |
| Cooling Method | Intelligent forced air cooling |
| Noise Level | |
| AC 208/400 V | < 65 dB(A) @ 1 m (Module) |
| AC 690 V | < 70 dB(A) @ 1 m (Module) |
| Dust Filter | Optional |
| Dimension | Please downlaod the brochure and refer to APF Model table |
| Weight | Please downlaod the brochure and refer to APF Model table |
| Environmental Requirement | |
| Ambient Temperature | -10~50°C |
| Relative Humidity | 0~95% (No condensation) |
| Altitude | ≤ 1000 m (Rated Capacity), 1000-3000 m (De-rating 1% per 100 m) |
| Rated Voltage | AC 400 V, AC 690 V |
| Input Voltage Range | |
| AC 400 V | AC 308~456 V, AC 308~480 V |
| AC 690 V | AC 384~880 V |
| Electric Connection | |
| AC 400 V | 3P4W, 3P3W |
| AC 690 V | 3P3W |
| Rated Frequency | 50(60) Hz ± 10% |
| Input Voltage THD Range | ≤ 15% |
| Rated Current per Module | |
| AC 400 V | 50 A, 75 A, 100 A |
| AC 690 V | 100 A |
| Rated Current per Cabinet | |
| AC 400 V | 50~700 A (Module combination) |
| AC 690 V | 100~500 A (Module combination) |
| Redundancy | Each module is an independent filtering system |
| Harmonic Elimination Range | |
| AC 400 V | 2nd~50th order (Selectable) |
| AC 690 V | 2nd~31st order (Selectable) |
| Harmonic Filtering Degree | 0~100% programmable per harmonic in Ampere value |
| Harmonic Filtering Performance | Filter up to 98% harmonics at rated load |
| THDv < 3%, THDi < 5% after filtering | |
| Reactive Power Compensation Capability | Both inductive and capacitive reactive power |
| Reactive Power Compensation Performance | PF ≥ 0.99 after compensation (if the APF capacity is sufficient) |
| Imbalance Correction Capability | |
| AC 400 V | Mitigate negative and zero sequence |
| AC 690 V | Mitigate negative sequence |
| Full Response time | < 20 ms |
| Instant Response time | < 100 us |
| Thermal Loss | ≤ 3% of APF rated capacity (kVA) |
| Output Current Limitation | Automatic (100% rated capacity) |
| Parallel Expansion(System) | Up to 10 Racks (7 modules per cabinet) |
| MTBF | > 100,000 hours |
| Switching Frequency | |
| AC 400 V | 60 kHz, 30 kHz |
| AC 690 V | 30 kHz |
| Controller | DSP control |
| Communication | Modbus RTU (RS-485), Modbus TCP/IP (Ethernet) |
| Physical Specification | |
| IP Grade of Cabinet | IP20, IP30, IP42, IP54 or customization |
| Cooling method | Intelligent forced air cooling |
| Noise Level | |
| AC 400 V | < 65 dB(A) @ 1 m (Module) |
| AC 690 V | < 70 dB(A) @ 1 m (Module) |
| Dust Filter | Optional |
| Dimension | Please downlaod the brochure and refer to APF Model table |
| Weight | Please downlaod the brochure and refer to APF Model table |
| Ambient Temperature | |
| Rear connection type | -10~50°C with 100% capacity, de-rating running from 50~55°C |
| Front connection type | -25~40°C with 100% capacity, de-rating running from 40~55°C |
| Relative Humidity | 0~95% (No condensation) |
| Altitude | ≤ 1000 m (Rated Capacity), 1000-2000 m (De-rating 1% per 100 m) |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
- Multifunctional: Harmonic, reactive power and imbalance compensation
- Harmonic Elimination Range: 2nd~50th order (Selectable)
- High harmonic filtering rate: Up to 98%
- Excellent reactive compensation: High speed, Precise (-0.99 ≤ PF≤ 0.99), Step-less, Bi-directional (capacitive and inductance) compensation
- Excellent imbalance correction: Both negative and zero sequence, mitigates neutral current
- Wide input voltage & frequency range, adapts to tough electrical environments
- Low thermal loss and high efficiency
- High stability: Infinite impedance to grid, avoids harmonic resonance problems
- Flexible application: Modular design, embedded in standard or customized cabinet
- Easy installation and maintenance: Plug-in installation for APF module replacement and expansion
- Wide capacity range: 30~750 A for a single cabinet, up 10 cabinets in parallel
- Environmental adaptability: -10~50°C ambient temperature, compatible with diesel generator
- Complete protection: Grid Over/Under voltage, APF over current, over temperature, and more. All faults are recorded in the event log, which is convenient for failure analysis
- Waveform display function on HMI: Display waveform of input Voltage, Grid current, Load current and APF current
- Display Harmonic current Histogram on HMI: Grid harmonic current and load harmonic current
- CTs’ reversal auto correction can be setted on HMI, support grid side or load side current detection
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● ● ● ● ●
Downloads
- Delta Active Power (Harmonic) Filter – datasheet (PDF)
- Power Quality Solutions – Rear/Front Connection Type (Brochure)
- Active Power Filter – Mixed Fixed Type, 400V (User Manual)
- Active Power Filter (User Manual)
Buy & Support
Somet Integration is the official distributor of Delta Electronics critical-infrastructure products in Israel. We provide project sizing, quotations, delivery, installation, commissioning, maintenance contracts and battery replacement.
Request a quote
Get local pricing, availability, sizing and installation for the Delta Active Power (Harmonic) Filter from Somet Integration.
Prefer to talk? Call 1-700-700-193, email somet@sometltd.com or message us on WhatsApp.