Delta Liquid-to-Liquid Coolant Distribution Unit, GoCool-1000
Delta · Data Center · Cooling
The increasing demand for high-performance computing and advanced GPUs highlights the limitations of aircooling.
- Maximize energy saving: cuts power consumption, surpassing traditional air cooling
- Space optimization: compact design enables closer server placement further reducing Capex
- Uninterrupted operation: dual power feed with ATS ensures continuous CDU operation
- Optimized redundancy design: ensures no single point of failure in the system
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta Liquid-to-Liquid Coolant Distribution Unit, GoCool-1000
The increasing demand for high-performance computing and advanced GPUs highlights the limitations of aircooling. Delta’s GoCool L2L CDU offers a superior alternative, providing effective separation of facility and secondary circuits as well as precise control over flow, pressure, temperature, and coolant quality. It excels in managing high-density thermal load, maximizing computing power while minimizing data center PUE. The GoCool L2L CDU ensures operational reliability by preventing condensation and guarantees quality with its stainless steel plumbing and coolant filtration. Elevate your data center performance—engineered for the future of high-performance computing.
Part of the Delta Data Center Infrastructure portfolio · Cooling.
| Model | GoCool-1000 |
| Nominal Cooling Capacity | 1000 kW @5°C approach, 1000 LPM secondary flow rate, 1200 LPM primary flow rate, 1.0 LPM/kW |
| 750 kW @4°C approach, 1125 LPM secondary flow rate, 1200 LPM primary flow rate, 1.5 LPM/kW | |
| Primary Side | |
| Coolant Type | Water |
| Nominal Coolant Flow Rate | 1200 LPM, 17°C primary inlet temperature |
| Operation Pressure Drop | 136 kPa |
| Secondary Side | |
| Coolant Type | 25%PG |
| Nominal Coolant Flow Rate | 1000 LPM |
| Approach Temperature | 5°C |
| Coolant Filter | 50 μm with isolation valves to enable hot-swappable (upgradeable to 25 μm) |
| External Pressure Drop | 360 kPa |
| Power Supply | |
| Nominal Power Supply Voltage | 380/400/415/480 Vac, 3P3W+PE |
| Operating Voltage Range | 342-528 Vac |
| Frequency | 50/60 Hz |
| Dual Power Feed | Standard |
| Automatic Transfer Switch | Standard |
| DC UPS Backup Power | Standard |
| MCU Controls | Standard |
| Power Feeds Location | Top |
| Deployment | |
| Primary Connection | 4″ Victaulic |
| Secondary Connection | 4″ Victaulic |
| Piping Connection Location | Bottom/Top |
| Physical | |
| Dimensions (W x D x H) | 900 x 1360 x 2300 mm |
| Clearance | Front: 900 mm, Rear: 900 mm |
| Net Weight | With coolant: 1800 kg, Without coolant: 1500 kg |
| Noise Level | < 79 dBA (at 1 m) |
| Communication Interface | |
| Display | 10″ color touchscreen |
| Protocols | SNMP, Modbus RTU, Modbus TCP/IP, BACnet |
| Monitoring | Primary Side: Temp. (Inlet/Outlet), Flow rate, Pressure (Inlet/Outlet, Filter ΔP) |
| Secondary Side: Temp. (Supply/Return), Flow rate, Pressure (Supply/Return, Filter ΔP) | |
| Dew-point Temp. | |
| Conformance | |
| Safety | CE |
| Features | |
| ⦁ Leak Detection | Standard |
| ⦁ Dew Point Monitor | Standard |
| ⦁ Control Sensor Redundancy | Standard |
| ⦁ Variable Frequency Drivers (VFD) | Standard |
| ⦁ Expansion Vessel | Standard |
| ⦁ Filling Tank | Optional |
| ⦁ Auto-restart Function | Standard |
| ⦁ Coolant Healthy Measurement | Optional |
| ⦁ Grouping Control | Standard |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
Cost Effective
- Maximize energy saving: cuts power consumption, surpassing traditional air cooling
- Space optimization: compact design enables closer server placement further reducing Capex
- Flexible integration: supports direct-to-chip and Rear Door Heat Exchanger (RDHx) application, adapting to existing setups and blending air and liquid cooling for future upgrades
High Reliability
- Uninterrupted operation: dual power feed with ATS ensures continuous CDU operation
- Optimized redundancy design: ensures no single point of failure in the system
- Leak detection: instant alarms with configurable response for efficient pumping action
- Durable construction: stainless steel plumbing with 50-micron filters for long-term coolant quality
Easy Management
- Intuitive interface: 10-inch color touchscreen displays real-time system status
- Efficient control: group and manual control enhance system management and reliability
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● ● ● ● ● ● ● ● ● For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.