Delta RT Series UPS, Single Phase, 1/2/3 kVA
Delta · UPS · Amplon
The Amplon RT 1-3kVA series is an online double-conversion UPS providing consistent sine-wave power to your critical equipment.
- Models: RT-1K, RT-2K, RT-3K
- True online double-conversion topology and zero transfer time to battery ensure high reliability.
- Watch-dog design of DSP (Digital Signal Processor) increases reliability.
- Cold-start capability provides temporary battery power when the utility power is out.
- Fan failure detection alerts users to failed fans.
Supplied in Israel by Somet Integration, official Delta distributor — sizing, installation, commissioning and service from our team in Lod.
Delta RT Series UPS, Single Phase, 1/2/3 kVA
Reliable power with greater energy-saving features
The Amplon RT 1-3kVA series is an online double-conversion UPS providing consistent sine-wave power to your critical equipment. It supports personal computers, networks, servers, VoIP and telecommunications. The Amplon RT 1-3kVA series features an output power factor of 0.9 and best-in-class AC-AC efficiency up to 94% resulting in greater energy savings. Optional external battery pack can be connected for longer backup time to keep your applications safe and running smoothly at all times.
Part of the Delta UPS Systems portfolio · Amplon.
| Model | Rating | |
| RT-1K | 1 kVA / 0.9 kW | View model » |
| RT-2K | 2 kVA / 1.8 kW | View model » |
| RT-3K | 3 kVA / 2.7 kW | View model » |
| Model | RT-1K / RT-2K / RT-3K |
| Power Rating | |
| RT-1K | 1 kVA / 0.9 kW |
| RT-2K | 2 kVA / 1.8 kW |
| RT-3K | 3 kVA / 2.7 kW |
| Input | |
| Nominal Voltage | 200*/208*/220/230/240 Vac |
| Voltage Range | 175-280 Vac (full load) |
| 120-175 Vac (70-100% load) | |
| Frequency | 40~70 Hz |
| Power Factor | > 0.99 (full load) |
| Current Harmonic Distortion | < 5% |
| Output | |
| Power Factor | 0.9 |
| Voltage | 200*/208*/220/230/240 Vac |
| Voltage Regulation | ± 1% (linear load) |
| Frequency | 50/60 Hz ± 0.05 Hz |
| Voltage Harmonic Distortion | < 2% (linear load) |
| Overload Capability | < 105%: Continuous |
| 105-125%: 1 minute | |
| 125-150%: 15 seconds | |
| Receptacle | |
| RT-1K | IEC C13 x6 |
| RT-2K/3K | IEC C13 x6, IEC C19 x1 |
| AC-AC | |
| RT-1K | 90% |
| RT-2K/3K | Up to 94% |
| ECO Mode | |
| RT-1K | 96% |
| RT-2K/3K | Up to 97% |
| Battery Voltage | |
| RT-1K | 24 Vdc |
| RT-2K | 48 Vdc |
| RT-3K | 72 Vdc |
| Typical Backup Time** | |
| RT-1K | 6.5 minutes |
| RT-2K/3K | 7 minutes |
| Charge Current | |
| RT-1K | 1.5 A |
| RT-2K/3K | 2 A |
| Recharge Time | 3 hours to 90% |
| Audible Noise | |
| RT-1K | < 40 dBA |
| RT-2K | < 43 dBA |
| RT-3K | < 46 dBA |
| Display | LCD display and LED indicators |
| Interfaces | SMART Slot x1, RS-232 Port x1, USB Port x1, REPO x1 |
| Conformance | CE, TISI, RCM, EAC |
| UPS | |
| RT-1K | 440 x 335 x 89 mm |
| RT-2K | 440 x 432 x 89 mm |
| RT-3K | 440 x 610 x 89 mm |
| External Battery Pack | |
| RT-1K | 440 x 335 x 89 mm |
| RT-2K | 440 x 432 x 89 mm |
| RT-3K | 440 x 610 x 89 mm |
| UPS | |
| RT-1K | 12 kg |
| RT-2K | 18 kg |
| RT-3K | 28 kg |
| External Battery Pack | |
| RT-1K | 15 kg |
| RT-2K | 27 kg |
| RT-3K | 44 kg |
| Environment | |
| Operating Temperature | 0 to 50°C*** |
| Relative Humidity | 5-95% (non-condensing) |
Specifications per Delta Electronics; subject to change without prior notice. Contact Somet Integration to confirm the exact configuration for your project.
Availability
- True online double-conversion topology and zero transfer time to battery ensure high reliability.
- Watch-dog design of DSP (Digital Signal Processor) increases reliability.
- Cold-start capability provides temporary battery power when the utility power is out.
- Fan failure detection alerts users to failed fans.
- Hot swappable batteries ensure continuous operation even when batteries are being replaced.
- Optional external battery pack for easy scaling of longer backup time.
- Operation temperature tolerance up to 50°C ensures critical loads’ continuity
Green & Low TCO
- High output power factor 0.9 provides more real power to critical loads.
- High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%) save upstream investment.
- Up to 94% AC-AC efficiency and 97% efficiency in ECO mode result in marked energy cost savings.
- Wide input voltage range reduces the chance of using the battery and extends battery life.
- Intelligent battery management sustains battery life and performance.
- Fan speed control by load level maximizes efficiency and reduces audible noise.
Flexibility
- Load segment control allows less-critical loads to be disconnected during blackouts and saves battery runtime for important loads.
- Convertible rack and tower configuration in 2U size cabinet.
- Excellent local communications through rotatable LCD display.
- Intelligent management software connectivity via RS232 or USB port.
- Product available regions : EMEA North America Latin America SEA & OCEA India China Taiwan South Korea Japan ● 120 V ● 120 V 100 V For region-specific product details and variations in specifications, please download the local leaflet or visit the local website.
Downloads
- Delta RT Series UPS, Single Phase, 1/2/3 kVA – datasheet (PDF)
- RT Series 1/2/3 kVA UPS 120V (Leaflet) : for North America
- RT Series 1/2/3 kVA UPS (User Manual)
- RT Series 1/2/3 kVA UPS – External Battery Pack (Quick Guide)
- RT Series 1/2/3 kVA UPS – External Charger Box (Quick Guide)
- R/RT Series 1/2/3 kVA UPS – Maintenance Bypass Box (Quick Guide)
Buy & Support
Somet Integration is the official distributor of Delta Electronics critical-infrastructure products in Israel. We provide project sizing, quotations, delivery, installation, commissioning, maintenance contracts and battery replacement.
Request a quote
Get local pricing, availability, sizing and installation for the Delta RT Series UPS, Single Phase, 1/2/3 kVA from Somet Integration.